WWW国产精品内射老熟女,欧美人妻第一页一区,欧美综合一区二区综合,色妺妺AⅤ爽爽一区二区

產(chǎn)品簡介
HG34e/215-4S HGX34e/215-4S
產(chǎn)品價格:¥12000.00元/個
上架日期:2025-06-13
發(fā)貨地:福建 福州市
供應(yīng)數(shù)量:不限
最少起訂:1個
瀏覽量:625
詳細說明
    詳細參數(shù)
    品牌德國GEA-Bock型號HG34e/215-4SHGX34e/215-
    工作原理其他冷卻方式風冷
    排氣量類型中型排氣量49,20/59,00m3/h
    排氣壓力類型中壓式排氣壓力42mm-15/8,
    固定方式固定式潤滑情況無油潤滑式
    原動機類型柴油機驅(qū)動氣缸中心線與地面相對位置臥式
    壓縮次數(shù)多級作用方式雙作用式
    缸徑×缸數(shù)4/41,5mm/40mm功率6.0kW
    額定轉(zhuǎn)速18,80/22,60m3/h氣桶容積535/282/318mm
    電壓220-240V,/380-420VY-噪聲低音
    適用領(lǐng)域船舶電源型式INT69GP66
    加工定制外形尺寸3171mm*1783mm*1963mm
    重量97kg壓縮介質(zhì)空氣
    用途其他傳動方式皮帶傳動
    產(chǎn)地德國

    HG34e/215-4S  HGX34e/215-4S

    福州天行健16年專業(yè)德國GEA-Bock原廠船用壓縮機及零部件

    福州天行健節(jié)能科技有限公司專業(yè)提供進口船舶零部件




    HG sin-tage compressors
    The HG model series consists of state-of-the-art classical suction gas-cooled compressor technology.
    Special features:
    - Outstanding running comfort
    - Efficiency and reliability on the highest level of quality
    - Service-friendly, e.g. replaceable drive motors
    - Oil pump lubrication
    - Electronic motor protection
    - Suitable for conventional or chlorine-free HFC refrigerants
    HG…e
    Those compressors are efficiency optimised models.
    By technical optimisations the motor-efficiency, gas flow and efficiency of the valve system are improved.、


    Semi-hermetic suction gas-cooled reciprocating compressor in compact design. The best possible serviceability is provided by means of a replaceable drive motor, among other things. The compressor stands out due to its outstanding running comfort and efficient operating perbance. The suction shut-off valve can be rotated by 90° in each instance. Dependable mechanism lubrication is guaranteed by means of an oil pump which is independent of rotating direction, as well as a large-volume oil sump. An electronic motor protection uses PTC sensors in series to monitor the winding temperature and, if desired, the discharge gas temperature.

    Colour: blue (RAL 5000)

    Technical data

    HGX34e/215-4 S

    Application Refrigeration & AC

    Compressor refrigeration capacity 9.54 kW

    Power consumption 3.03 kW

    Current draw (400 V) 6.93 A

    Mass flow 0.067 kg/s

    at following operating condition:

    Refrigerant R134a

    Reference temperature Dew point

    Evaporating temperature 5.0 °C

    Condensing temperature 50.0 °C

    Supply frequency 50 Hz

    Voltage 400 V

    Suction gas temperature 20 °C

    Subcooling (outside cond.) 0 K

    Number of cylinders / Bore / Stroke 4 / 41,5 mm / 40 mm

    Displacement 50/60 Hz (1450/1740 1/min) 18,80 / 22,60 m3/h

    Voltage 1) 220-240V Δ / 380-420V Y -3- 50Hz

    265-290V Δ / 440-480V Y -3- 60Hz

    Max. working current 2) 18.3 / 10.5 A

    Max. power consumption 2) 6.0 kW

    Starting current (rotor blocked) 2) 132.0 / 76.0 A

    Motor protection INT69 G

    Protection terminal box IP 66

    Weight 97 kg

    Max. permissible overpressure (g) (LP/HP) 3) 19 / 28 bar

    Connection suction line SV 28 mm - 1 1/8 "

    Connection discharge line DV 22 mm - 7/8 "

    Lubrication Oil pump

    Oil type R134a, R404A, R407A/C/F, R448A, R449A, R450A, R513A BOCKlub E55

    Oil type R22 BOCKlub A46

    Oil charge 1,3 Ltr.

    Dimensions Length / Width / Height 535 / 282 / 318 mm

    Sound power level LWA 4) 69 db(A) @ -35/+40 °C

    67 db(A) @ -10/+45 °C

    66 db(A) @ +5/+50 °C

    Sound pressure level LpA 4) 57 db(A) @ -35/+40 °C

    54 db(A) @ -10/+45 °C

    54 db(A) @ +5/+50 °C

    Scope of supply

    Semi-hermetic four cylinder reciprocating compressor with drive motor

    Single-section compressor housing with hermetically integrated electric motor

    Oil pump

    Winding protection with PTC resistor sensors and electronic trigger unit INT69 G

    115-230 V AC, 50/60 Hz, IP00

    Possibility for connection of oil pressure safety switch MP55

    Possibility of connection of oil level controllers ESK, Traxoil, AC+R or CARLY 5)

    Oil charge:

    HG: BOCKlub A46

    HGX: BOCKlub E55

    Sight glass

    Suction and discharge line valve

    Inert gas charge

    4 anti-vibration pads enclosed

    Accessories

    Start unloader by means of a ESS (Electronic Soft Start), 400 V - 3 - 50/60 Hz, IP20 (Connection clamps IP00) for installation in switch cabinet 6)

    (Digital) capacity regulator DCR14 230 V - 1 - 50/60 Hz, IP65

    possible equippment see 09900-DGbF Capacity regulator 09900-DGbF

    Cylinder cover prepared for digital capacity regulator

    Oil sump heater

    110-240 V - 1 - 50/60 Hz, 50-120 W, IP66

    PTC heater self-regulating

    Thermal protection thermostat per cylinder cover 7)

    Oil pressure safety switch MP55 230 V - 1 - 50/60 Hz, IP20 6)

    USB converter for INT69 G Diagnose 6)

    INT69 G Diagnose 115-230 V AC, 50/60 Hz, IP00 (INT69 G not applicable)

    DP-Modbus Gateway 115-230 V AC, 50/60 Hz, IP00 including adapter cable 6)

    Modbus-LAN Gateway 230 V AC, 50/60 Hz, IP00 6)

    Additional fan

    230 V AC - 1 - 50 Hz, 97 W, IP44

    230 V AC - 1 - 60 Hz, 128 W 6)

    Step protection

    Special voltage and/or frequency (on request)

    Notes

    1) Tolerance (± 10%) relates to the mean value of the voltage range. Other voltages and current types on request

    All data are based on voltage rms values

    2) - The stated value for the max. power consumption is valid for the adjusted power supply.

    - Starting current (rotor blocked):

    Part winding (PW) motors: Winding 1 / Winding 1+2

    Delta/Star (Δ/Y) motors: Δ / Y

    - Take account of the max. operating current / max. power consumption for designing fuses, supply lines and safety devices. Fuse: Consumption category AC3.

    3) LP = Low pressure

    HP = High pressure

    4) Declared dual-number noise emission values are in accordance with ISO 4871. The corresponding uncertainty to the sound power level is KWA = 2,5 dB and to the sound pressure level is KpA = 2,5 dB. The values are valid for 50 Hz with the refrigerant R404A at the standard rating points according to EN 12900.

    A-weighted sound power level LWA (re 1 pW), in decibel. To determine the values, measurement bs of the ISO 3740 standard with accuracy class 2 or higher were used .

    A-weighted sound pressure level LpA (re 20 μPa), in decibel. The values are calculated from the sound power level in accordance with ISO 11203: LpA = LWA - Q2 at a distance of d = 1m to the reference box.

    5) Only with additional adapter possible

    6) Enclosure

    7) Mounted


在線詢盤/留言
  • 免責聲明:以上所展示的信息由企業(yè)自行提供,內(nèi)容的真實性、準確性和合法性由發(fā)布企業(yè)負責,本網(wǎng)對此不承擔任何保證責任。我們原則 上建議您選擇本網(wǎng)高級會員或VIP會員。
    0571-87774297